Skip to content

Stiebel Eltron DHC-E 12/15 - 2 Trend Point-of-Use Electric Tankless Water Heater - 200059

1 Review
SKU 200059
Original price $399.00 - Original price $399.00
Original price
$399.00
$399.00 - $399.00
Current price $399.00
Availability:
Low stock

The Stiebel Eltron DHC-E 12/15 - 2 Trend Point-of-Use Electric Tankless Water Heater - 200059 features the innovative Direct Coil™ heating system, this model is designed for both efficiency and durability. It operates on a 240/208V power supply, offering a 12.0/14.4 kW output that ensures immediate hot water without the wait. Notably, its tankless design is both space-saving and energy-efficient, boasting a 99% efficiency rate. The heater is built to resist limescale build-up, maintaining its performance and extending its lifespan. Additionally, the unit features a backlit digital display for easy temperature control, making it an ideal solution for residential and commercial applications where space and efficiency are important.

Features:

  • Direct Coil heating system’s proven and trouble-free technology self-cleans for increased limescale resistance
  •  Switchable kW power output means each model can cover more applications
  •  The backlit display shows the current temperature
  •  Easily adjustable temperature (68-140 °F) via a knob on the front cover
  •  Ideal for many commercial applications, including bathrooms, break rooms, utility sinks, or a single low-flow shower
  •  Heats water on demand, for endless water as long as it is needed
  •  Electronic self-modulation technology ensures the least amount of electricity needed is used
  •  Sleek European design is considerably smaller than a tank, requires no venting, and allows space-saving installation close to the point-of-use
  •  Direct Coil heating system provides fast heat-up and response
    Carbon-neutral shipping with Shopify Planet
    Carbon-neutral shipping on all orders
    3,052kg
    shipping emissions removed
    That's like...
    7,812
    miles driven by an average gasoline-powered car
    We fund innovations in...
    Direct Air Capture
    Bio Oil
    Mineralization

    Specifications

    Model DHC-E 4/6-2 Trend

    DHC-E 8/10-2 Trend 

    DHC-E 8/10-2 Plus

    DHC-E 12/15-2 Trend 

    DHC-E 12/15-2 Plus

    Item no.200061

    200058 (Trend) 

    202145 (Plus)

    200059 (Trend) 

    200056 (Plus)

    Phase - 50/60 Hz1
    Voltage240 V208 V240 V208 V240 V208 V
    Wattage (1) , Jumper Position 1 [Low] / 2 [High]3.8 kW / 6 kW2.9 kW / 4.5 kW7.2 kW / 9.6 kW5.4 kW / 7.2 kW12 kW / 14.4 kW9 kW / 10.8 kW
    Amperage, Jumper Position 1 [Low] / 2 [High]15.8 A / 25 A13.9 A / 21.7 A30 A / 40 A26 A / 34.6 A50 A / 60 A43.3 A / 52 A
    Min. Recommended Circuit Breaker Size (2) , Jumper Position 1 [Low] / 2 [High]20 A / 25 A15 A / 25 A30 A / 40 A30 A / 35 A50 A / 60 A50 A / 60 A
    Min. Recommended Awg Wire Size (3) , Jumper Position 1 [Low] / 2 [High12/2 / 10/214/2 / 10/210/2 / 8/2 10/2 / 8/28/2 / 6/28/2 / 6/2
    Minimum Water Flow to Activate Unit0.264 gpm (1.0 l/min)
    Max Flow Rate (GPM) @ 42°F0.5 GPM / 0.85 GPM1 GPM / 1.4 GPM1.7 GPM / 2 GPM
    Max Flow Rate (GPM) @ 52°F0.7 GPM / 1.o GPM0.9 GPM / 1.5 GPM1.4 GPM / 2.3 GPM
    Max Flow Rate (GPM) @ 62°F1.3 GPM / 1.7 GPM1.8 GPM / 2.3 GPM2.7 GPM / 3.6 GPM
    Max Flow Rate (GPM) @ 72°F2.2 GPM / 2.6 GPM2.9 GPM / 3.5 GPM4.6 GPM / 5.5 GPM
    Weight5.5 lb (2.5 kg)
    DimensionsHeight 14 1/8" (360 mm) x Width 8" (202 mm) x Depth 4 5/16" (109 mm) 
    Nominal Water Volume0.07 gal (0.277 l)
    Max. Permissible Inlet Temperature149 °F (65 °C)
    Maximum Permissible Pressure145 psi (10 bar)
    Water Connections (3)½" NPT

     

    DHC-E 3/3.5-1 Trend and 4/6-2 Trend ship with pressure compensating flow-reducer/aerators that must be installed. 

    1. Factory default setting is jumper position 2 [high]
    2. Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
    3. Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load. 

     

    These are recommendations. Check local codes for compliance if necessary